Product Information
The Chattanooga Hydrocollator M-4 is a high-capacity mobile moist-heat therapy unit for demanding professional workflows. Thermostatic regulation maintains the working water-temperature range, while the mobile base supports careful relocation within clinical facilities.
Fiberglass-insulated stainless-steel construction combines heat retention, durability, and serviceability. Automatic low-water protection helps safeguard the heating system during operation.
Product Features
High-capacity heat storage supports busy professional workflows, while thermostatic temperature control maintains the specified moist-heat operating range.
A mobile clinical design and fiberglass-insulated stainless-steel tank balance relocation, durability, and thermal performance.
Chattanooga Hydrocollator Mobile Moist Heat Therapy Unit M-4 with 24 Standard Packs
High-volume thermal capacity:
The large tank supports sustained professional moist-heat preparation in active treatment environments.
Regulated operating heat:
Thermostatic control maintains the water within the specified therapeutic operating range.
Controlled clinical mobility:
The wheeled cabinet can be repositioned carefully and secured before normal operation.
Insulated stainless tank:
Fiberglass insulation helps retain heat while stainless steel supports durability and routine care.
About Chattanooga
Chattanooga is a long-established rehabilitation equipment brand known for clinical therapy products used by physical therapists, chiropractors, athletic trainers, and rehabilitation professionals. Its treatment systems are designed for dependable use in professional care settings.
Why Choose Us?
Choose Peak Primal Wellness for a personalized, community-driven approach to health. We prioritize your well-being with high-quality products, tailored solutions, and 24/7 support.
As a family-owned business, we build lasting relationships, offering authentic, effective solutions to help you achieve your wellness goals.
Join our thriving community and embark on a journey toward optimal health with passionate professionals who genuinely care. At Peak Primal Wellness, you're not just a customer—you're family.
Them
Returns & Warranty
Return & Warranty
Before you spend alot of money with anybody Vet Them. Us included
Read Independent Reviews
Read their reviews where they can't curate them, Trustpilot, not their own widget; read the one-star reviews and watch how they respond when freight goes sideways. You can see our Trustpilot reviews here
Ask About Damage Claims
Ask what happens when a unit arrives damaged, you're listening for a person who owns it, not store-blames-manufacturer ping-pong.
Confirm Delivered Pricing
Get the delivered price in writing before payment, "freight quoted after purchase" is the oldest move in the category.
Get a Contact Name
Ask for a name, if nobody owns your order, nobody owns your problem.
Specifications
| Mains Input Power | 110–120 V, 50/60 Hz |
| Rated Power Consumption | Rated 1000 watts |
| Standard Unit Weight | 132 lb / 60 kg |
| Packaged Shipping Weight | 160 lb / 65 kg |
| Overall Unit Dimensions | 35 × 20 × 33 inches |
| Metric Unit Dimensions | 89 × 51 × 84 cm |
| Electrical Safety Class | Class I, Type B |
| Approximate Tank Capacity | 27 gal / 102 L |
| Operating Temperature Range | 160–165°F / 71–74°C |
| Thermal Cutout Range | 180–185°F / 82–85°C |
| Temperature Control Accuracy | Within ±10 percent |
| Heating Cycle Time | Approximately eight hours |
| Cooling Cycle Time | Approximately four hours |
| Fiberglass Insulation Included | Yes, fiberglass insulated |
| Applicable Safety Standards | UL 60601-1; CAN/CSA-C22.2 No. 601.1-M90 |
Warranty & Returns
Warranty Information
Warranty coverage may vary by manufacturer and product configuration. Please contact Peak Primal Wellness before purchase or service request for current Chattanooga warranty details for this product.
Return Policy
To request a return or refund, customers can use our contact form, email (info@peakprimalwellness.com) , or phone - (877) 689-4898. Once the product is inspected and confirmed to be in brand new condition, we will initiate the refund, which typically takes 5-7 business days to post back to the original payment method. Refunds can be applied via the customer’s preferred method, including card or bank transfer. Shipping instructions and the return address will be provided upon contacting customer service. Please include photos if the product arrives damaged. Click here to view our complete return policy for more details.
Shipping Policy
Customers may contact us by phone or email anytime to inquire about the status of their order. While we may not always have a tracking link available before the order ships, we are happy to check its current status for you. If an item is never received, please contact us immediately. We will promptly file a claim on your behalf and ship a replacement to ensure you receive your product as soon as possible. Click here to view our complete Shipping policy for more details.
Frequently Asked Questions
How does thermostatic operation regulate heat?
The thermostat cycles the heater to maintain water within the designated professional moist-heat operating range.
Why must the water level be monitored?
Maintaining the prescribed level supports even heating and prevents activation of the low-water protective shutdown.
What affects the initial heat-up period?
Starting water temperature, tank volume, room conditions, and lid use can influence the time required.
What does the thermal cutout do?
It interrupts heating if temperature rises beyond the normal control range and requires proper service evaluation.
How should water temperature be monitored?
Check the thermometer and thermostat operation routinely, following the operating manual and facility procedures.
When should the tank be cleaned?
Clean it at the intervals specified in the operating instructions and whenever mineral deposits or contamination appear.
How should tank water be replaced?
Disconnect power, allow safe cooling, drain carefully, clean the tank, and refill to the prescribed level.
How should the casters be used safely?
Unlock casters only for careful relocation, avoid moving a filled hot unit when possible, and secure it before operation.
How should stainless steel be maintained?
Use approved nonabrasive cleaning methods, rinse residues thoroughly, and avoid materials that can damage the finish.
What is the proper shutdown procedure?
Switch off and disconnect power before draining, cleaning, inspection, extended storage, or authorized service.