Richmar TheraTouch LX2 Therapeutic Laser System with Cluster Applicator

Richmar SKU: 13-3415
Preview Icon

Official Distributor

Regular price $3,699.95
Sale price $3,699.95 Regular price $3,675.00
Preview Icon

Starts at: $924.98/mo Learn More

Or

Monthly payments start at: $924.98/mo Learn More

Ships in 1-5 days at most



Regular price $3,699.95
Sale price $3,699.95 Regular price $3,675.00
Truck Icon

Free Shipping

Free Shipping on Most Products
for Orders over $200

on Most Products
Phone Icon

Call Us

(877) 689-4898
Mon-Fri 9am-5pm (CST)

Low Price Icon

Lowest Price Guaranteed

Lowest price guaranteed
on products

Return Icon

Easy Returns

Always hassle free

Product Information

The Richmar TheraTouch LX2 is a Class IIIb cold-laser therapy system designed to support clinical laser-light treatment setup through selectable clinical protocols and adjustable treatment parameters. It is built around a full-color touchscreen interface, dosage calculation, and laser applicator options for controlled light delivery.
Richmar designed the Richmar TheraTouch LX2 Laser Light Device with Cluster for clinical workflows that require controlled parameter selection, clear setup guidance, and repeatable treatment operation.

Large Image
Small Image 1 Small Image 2

Product Features

Class IIIb laser-light therapy system capable of delivering up to 35 J/cm2 per treatment.

Standard 9-diode cluster applicator combines four 650 nm LED diodes and five 850 nm infrared laser diodes.

Continuous or pulsed output, programmable treatment time up to 4 minutes, 10 predefined clinical protocols, and up to 100 user-defined protocols.

Laser Icon
Class IIIb Laser System
Waves Icon
650 nm and 850 nm Wavelengths
Clinic Icon
10 Clinical Protocols
OutputIicon
Pulsed or Continuous Output
Product Image

Richmar TheraTouch LX2 Laser Light Device with Cluster

Laser-Light Therapy Platform:
The LX2 is a Class IIIb cold-laser therapy device with menu-driven treatment setup, real-time dosage display, and adjustable treatment parameters for clinical laser-light applications.

Cluster Applicator Configuration:
The standard cluster applicator uses four 650 nm wavelength LED diodes at 10 mW each and five 850 nm wavelength infrared laser diodes at 200 mW each, with total cluster power listed at 1040 mW.

Treatment Setup and Dosing:
The dosage calculator displays Joules, J/cm2, and J/diode, updating dosing values as treatment output is adjusted.

Protocol Workflow:
The system includes evidence-based clinical protocols, a tissue-healing protocol, and storage for up to 100 user-defined protocols.

About Richmar

Richmar develops clinical rehabilitation technologies for therapeutic ultrasound, clinical electrotherapy, laser-light therapy, shortwave diathermy, and related treatment environments. The Richmar TheraTouch LX2 Laser Light Device with Cluster fits within Richmar's clinical device lineup with treatment-specific controls, protocol guidance, and technical operation designed for professional care settings.

Richmar brand image

Why Choose Us?

Choose Peak Primal Wellness for a personalized, community-driven approach to health. We prioritize your well-being with high-quality products, tailored solutions, and 24/7 support.

As a family-owned business, we build lasting relationships, offering authentic, effective solutions to help you achieve your wellness goals.

Join our thriving community and embark on a journey toward optimal health with passionate professionals who genuinely care. At Peak Primal Wellness, you're not just a customer; you're family.

Why Thousands of Health and Fitness Lovers Choose Exercise

Peak Primal Wellness Logo

Them Green Thumb Depot Logo

icons-no Support
icons-no Nearly impossible to reach a real person. Endless chatbot loops, auto-replies, and unreturned emails.
icons-no Real humans. We answer quickly. Always here, always helpful
icons-no Order Processing
icons-no Orders often sit for days before being acknowledged. No clear confirmation, updates, or timelines.
icons-no Orders are processed immediately. You'll receive confirmation, tracking, and real-time updates within hours.
icons-no Shipping
icons-no Slow, vague, and unoptimized. Basic carriers, minimal tracking, and delayed delivery windows.
icons-no Fast, insured, and fully trackable shipping — optimized for speed and visibility every step of the way.
icons-no Pricing
icons-no Hidden fees, bait and switch tactics, post purchase price increases.
icons-no Our relationships guarantee the lowest prices. Transparent and fair. No surprises at checkout, and no shady tactics after the sale.
icons-no Returns & Warranty
icons-no Policies are confusing and designed to frustrate, delay, and deny returns with zero accountability.
icons-no Clear, honest, and fast. Our return policy is built to protect your investment, not dodge responsibility.
icons-no Support
icons-no Frustrating automated responses
icons-no Fast, helpful and always supportive
icons-no Order Processing
icons-no Delays and lack of communication
icons-no Instant processing and updates
icons-no Shipping
icons-no Slow, unreliable and delayed service
icons-no Fast, insured, trackable shipping
icons-no Pricing
icons-no Deceptive pricing practices
icons-no Lowest prices, no surprises
icons-no Return & Warranty
icons-no Frustrating, misleading return policies
icons-no Clear, honest return policy

Specifications

Brand Richmar
Product Name TheraTouch LX2 Laser Light Device with Cluster
Device Type Class IIIb cold-laser therapy device
Treatment Technology Laser and light therapy
Standard Applicator 9-diode cluster applicator
Cluster Wavelengths Four 650 nm LED diodes and five 850 nm infrared laser diodes
Cluster Output Four 10 mW LED diodes plus five 200 mW infrared laser diodes; 1040 mW total power
Optional Applicator Single 850 nm infrared laser diode applicator at 200 mW
Output Modes Continuous or pulsed
Pulsed Mode 90%
Emission Frequency 1 Hz-10000 Hz
Treatment Timer Programmable treatment time up to 4 minutes
Protocols 10 predefined clinical protocols
User-Defined Protocols Save up to 100 user-defined protocols
Display Type Full-color touchscreen interface
Electrical Requirements 100-240 V, 50/60 Hz
Manual Link Operational Manual

Warranty & Returns

Return Policy

To request a return or refund, customers can use our contact form, email , or phone - . Once the product is inspected and confirmed to be in brand new condition, we will initiate the refund, which typically takes 5-7 business days to post back to the original payment method. Refunds can be applied via the customer's preferred method, including card or bank transfer. Shipping instructions and the return address will be provided upon contacting customer service. Please include photos if the product arrives damaged. Click here to view our complete return policy for more details.

Shipping Policy

Customers may contact us by phone or email anytime to inquire about the status of their order. While we may not always have a tracking link available before the order ships, we are happy to check its current status for you. If an item is never received, please contact us immediately. We will promptly file a claim on your behalf and ship a replacement to ensure you receive your product as soon as possible. to view our complete Shipping policy for more details.

Frequently Asked Questions

How do the LX2 wavelengths differ in clinical use?
FAQ expand arrow icon

The LX2 cluster combines visible 650 nm LED diodes with 850 nm infrared laser diodes, giving clinicians separate light outputs within one cluster applicator for laser-light treatment setup.


How does the cluster applicator operate?
FAQ expand arrow icon

The standard cluster applicator uses nine diodes arranged as four 650 nm LED diodes and five 850 nm infrared laser diodes, allowing the applicator to deliver combined light output over the treatment area.


When would continuous or pulsed output be selected?
FAQ expand arrow icon

Continuous output provides steady light delivery, while pulsed output modulates emission according to selected treatment parameters and clinical protocol setup.


How does the dosage calculator support setup?
FAQ expand arrow icon

The dosage calculator displays Joules, J/cm2, and J/diode and updates values as output settings are changed, helping clinicians monitor dosing parameters.


What precautions matter during laser-light operation?
FAQ expand arrow icon

Clinicians should follow laser safety procedures, use appropriate eye protection, control applicator positioning, and operate the device according to the treatment protocol and manual guidance.